By Don Davies, Technical Director, Prosig
Shaft displacement is an important vibration measurement for rotating machines. Shaft displacement is usually monitored by non-contact shaft displacement probes such as eddy-current probes. These probes produce a voltage proportional to the distance of the shaft surface relative to the tip of the probe. For maximum benefit, ideally two shaft displacement probes will be fitted to measure the displacement in both the horizontal and vertical directions. Actually the probes do not have to be exactly horizontal and vertical as PROTOR (http://www.prosig.com/protor) is able to resolve into the horizontal and vertical directions.
read »»»
By James Wren, Application Engineer, Prosig
Most engineers are probably familiar with or have come across the decibel or dB as a unit of measurement. Its most common use is in the field of acoustics where it is used to quantify sound levels. However, as will be explained in this article, it is also useful for a wide variety of measurements in other fields such as electronics and communications.
One particular use of dB is to quantify the dynamic range and accuracy of an analogue to digital conversion system. This applies to Prosig’s P8000 range of data acquisition hardware where the noise floor, dynamic range and resolution are all specified in terms of dB. read »»»
By Dr Colin Mercer, Technical Director, Prosig

Any vibration signal may be analyzed into amplitude and phase as a function of frequency. The phase represents fifty percent of the information so it is most important to measure phase for vibration monitoring. Most vibrations on a rotating machine are related to the rotational speed so it is clearly important to have a measure of the speed, either directly or as a once per revolution tacho pulse. A question some time arises as to whether a once per revolution tacho reference signal is needed to measure phase. Is it possible to get phase if we only have a speed signal? This note gives some insight into those questions. Actually the question that should be asked is - “Can we measure a meaningful phase, for use in vibration monitoring, if we only have a speed signal as well as the vibration signals?” read »»»
By Dr Colin Mercer, Technical Director, Prosig
Standards DIN 4150-2:1999-06 and DIN 45669-1:1995-06 provide a means of assessing the effect on human beings of vibration caused by vehicle traffic, trains both above and below ground, construction work and occasional impulsive type vibration caused by, say, blasting and the like.
DIN 45669-1 describes the signal processing actions and DIN 4150-2 details how these are used. Provisions are included for day or night levels and for five categories of building:
- Industrial
- Predominantly Commercial
- Mixed Commercial and Residential
- Residential
- Special Areas such as Hospitals
read »»»
By Mike E Moore, VP Sales & Marketing, Prosig USA, Inc.
Using Prosig’s P8000 series data acquisition system with DATS signal analysis software, torsional analysis (crank jitter) was performed on an automotive engine attached to an engine dynamometer. The significance of this is that only one tachometer channel was required to identify crank jitter. read »»»
By James Wren, Application Engineer, Prosig
First, in order to explain resonance we have to explain the terms we will use.
• A resonance is a particular frequency.
• A period is the amount of time it takes to complete one cycle
• The number of cycles in one second is the frequency of an oscillation.
• Frequency is measured in Hertz, named after the 19th-century German physicist Heinrich Rudolf Hertz
• A single Hertz is equal to one cycle per second.
read »»»
By James Wren, Application Engineer, Prosig
Prosig were recently involved in the validation of a closed loop control system for an automotive pump supplier. The customer has a large number of test cells, each test cell has 8 pumps continually on test. Each pump is instrumented with a revolution or tachometer sensor, giving a once per revolution tachometer pulse. Additionally, there are various analogue transducers on each pump which measure parameters, such as pressure at the pump inlet and outlet. read »»»
By Dr Colin Mercer, Technical Director, Prosig
Accelerometers are robust, simple to use and readily available transducers. Measuring velocity and displacement directly is not simple. In a laboratory test rig we could use one of the modern potentiometer or LVDT transducers to measure absolute displacement directly as static reference points are available. But on a moving vehicle this is not possible.
More here… OmegaArithmetic.pdf
By James Wren, Application Engineer, Prosig
The following application note shows the steps taken to perform a structural analysis on an automotive exhaust pipe structure with the aim of improving the structural damping properties of the exhaust pipe mount. This application note is a follow up to a previous article – “Preventing Component Failure In The Fast Lane”.
A recent signal processing application note described how the Prosig sponsored Dalmeny Racing Formula Ford Team, whilst contesting the UK Formula Ford 1600cc championship, suffered several minor structural failures on a particular part of an exhaust pipe mount. Prosig dispatched a team of engineers and after a brief survey of the damage the Prosig engineers made an outline assessment “Our initial thoughts are that the exhaust itself might be resonating at particular engine speeds, thus causing some shear forces in the mount, which could then in turn cause stresses in the material leading to cracking and eventually failure.” read »»»
By James Wren, Application Engineer, Prosig
In this note the different types of transducers that can be used with the Prosig P8000 series data acquisition system are discussed. The article deals with the design and function of the different types of transducer and the applications they are normally associated with. read »»»
By Dr Colin Mercer, Technical Director, Prosig
A shaft has been instrumented with two shaft encoders, one at each end. Each shaft encoder gives out a once/rev pulse and a 720 pulses/rev signal. Each signal was digitised at 500,000 samples/second. The objective is to measure the twist in the shaft and analyze into orders. The test stand was already equipped with a data acquisition system so a Prosig acquisition system was not required. Instead it was decided that the data captured by the resident system would be imported into the DATS software. The only format available from the customer system was ‘comma separated variables’ or CSV. This is not ideal as it is an ASCII based format and therefore creates very large files. read »»»
In a recent article we described how the Prosig P8000 hardware and DATS software had been used to help Dalmeny Racing diagnose a problem with an exhaust bracket on their Formula Ford racing car. Whilst the car was instrumented for structural tests on the exhaust the opportunity was taken to also take some noise and vibration readings during an engine run up. It was felt that these would provide some useful “real world” data as well as maybe providing some extra information regarding the exhaust bracket failure. After analysing and animating the hammer data it became clear that the engine runup data wouldn’t be needed. However, it was decided that some analysis should be carried out to see if the noise and vibration data backed up the conclusions of the other tests. read »»»
By Dr Colin Mercer, Technical Director, Prosig
Accurate measurement of a signal depends on the dynamic range and the overall level of the data acquisition system. The overall level setting may be thought of as determining the largest signal that can be measured. This clearly depends on the present gain setting. That is the overall level is related to the gain. Clearly if the overall level is too small (gain too high) then the signal will be clipped and we will have poor quality data. The dynamic range then tells us that for the given overall level what is the smallest signal we can measure accurately whilst simultaneously measuring the large signal.
In a very simple sense suppose we have an artificial signal which consists of a sinewave at a large amplitude A for the first half and that this is followed by a sinewave with a small amplitude a for the second half. We will set the gain (the overall level) to allow the best measurement of the A sinewave. The dynamic range tells us how small a may be so we can also measure that without changing settings.
read »»»