Prosig Signal Processing Blog

Notes, tutorials, news and articles on digital signal capture, processing, techniques and applications

May 17, 2006

FATIGUE & DURABILITY TESTING

By James Wren, Application Engineer, Prosig

The following application note describes the test and measurement process for the fatigue testing and development cycle of a component. Strain gauges were used to monitor the strain levels in a particular suspension component. The component had been known to fail at various intervals. A predicted life for the component was required to analyse the feasibility of the its continued use or to see if a design change was required. The component under test (Figure 1) was an automotive suspension component, specifically a tie rod. The testing was carried out by a major automotive manufacturer. read »»»

February 20, 2006

EXHAUST DEVELOPMENT USING A PROSIG P8000 SYSTEM

By James Wren, Application Engineer, Prosig

The following note describes an application of the Prosig P8000/DATS system in the refinement of an automotive exhaust muffler design for a major after-market exhaust manufacturer in Europe. The particular vehicle under test was required by local legislation to have an overall radiated noise level of less than 70 dB. When tested, the vehicle was found to be producing 71.8 dB of radiated noise. The design of the exhaust system clearly needed to be reviewed and modified. read »»»

August 26, 2005

A SIMPLE NOISE TEST

In a recent article we described how the Prosig P8000 hardware and DATS software had been used to help Dalmeny Racing diagnose a problem with an exhaust bracket on their Formula Ford racing car. Whilst the car was instrumented for structural tests on the exhaust the opportunity was taken to also take some noise and vibration readings during an engine run up. It was felt that these would provide some useful “real world” data as well as maybe providing some extra information regarding the exhaust bracket failure. After analysing and animating the hammer data it became clear that the engine runup data wouldn’t be needed. However, it was decided that some analysis should be carried out to see if the noise and vibration data backed up the conclusions of the other tests. read »»»

May 15, 2002

TORSIONAL VIBRATION EXAMPLE

By Dr Colin Mercer, Technical Director, Prosig

The measurement of the twist angle between two points along a shaft or through a gear train may be derived from a pair of tacho signals, one at each end of the shaft. Typically the tacho signals would be derived from gear teeth giving a known number of pulses/revolution. For example one end of a shaft could have a gear wheel with say 60 teeth giving 60 pulses/revolutions when measured with say an inductive or eddy current probe. read »»»