<?xml version="1.0" encoding="UTF-8"?> <rss
version="2.0"
xmlns:content="http://purl.org/rss/1.0/modules/content/"
xmlns:wfw="http://wellformedweb.org/CommentAPI/"
xmlns:dc="http://purl.org/dc/elements/1.1/"
xmlns:atom="http://www.w3.org/2005/Atom"
xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
><channel><title>Prosig Noise &#38; Vibration Blog &#187; shaft : Noise &amp; Vibration Blog : What You Need To Know About Noise &amp; Vibration Measurement</title> <atom:link href="http://blog.prosig.com/tag/shaft/feed/" rel="self" type="application/rss+xml" /><link>http://blog.prosig.com</link> <description>Telling you what you need to know about noise &#38; vibration</description> <lastBuildDate>Wed, 25 Jan 2012 14:42:00 +0000</lastBuildDate> <language>en</language> <sy:updatePeriod>hourly</sy:updatePeriod> <sy:updateFrequency>1</sy:updateFrequency> <generator>http://wordpress.org/?v=3.3.1</generator> <item><title>Measuring Torsional Vibration 101</title><link>http://blog.prosig.com/2012/01/24/measuring-torsional-vibration-101/</link> <comments>http://blog.prosig.com/2012/01/24/measuring-torsional-vibration-101/#comments</comments> <pubDate>Tue, 24 Jan 2012 10:26:13 +0000</pubDate> <dc:creator>Chris Mason</dc:creator> <category><![CDATA[applications]]></category> <category><![CDATA[featured]]></category> <category><![CDATA[signal processing]]></category> <category><![CDATA[acoustic]]></category> <category><![CDATA[acoustic data]]></category> <category><![CDATA[acoustics]]></category> <category><![CDATA[aliasing]]></category> <category><![CDATA[analysis]]></category> <category><![CDATA[gear train]]></category> <category><![CDATA[gears]]></category> <category><![CDATA[jitter]]></category> <category><![CDATA[measurement]]></category> <category><![CDATA[noise]]></category> <category><![CDATA[prosig]]></category> <category><![CDATA[pulses]]></category> <category><![CDATA[refinement]]></category> <category><![CDATA[rotat]]></category> <category><![CDATA[rotation]]></category> <category><![CDATA[rotational]]></category> <category><![CDATA[rotational speed]]></category> <category><![CDATA[shaft]]></category> <category><![CDATA[shaft encoder]]></category> <category><![CDATA[signals]]></category> <category><![CDATA[tachometer]]></category> <category><![CDATA[torsional]]></category> <category><![CDATA[torsional vibration]]></category> <category><![CDATA[twist]]></category> <category><![CDATA[vibration]]></category><guid
isPermaLink="false">http://blog.prosig.com/?p=2875</guid> <description><![CDATA[Do you need to measure torsional vibration? Interested in shaft twist? Worried about rotational jitter? Don&#8217;t worry, we&#8217;ve got it covered. Here we have gathered together our most popular articles...]]></description> <wfw:commentRss>http://blog.prosig.com/2012/01/24/measuring-torsional-vibration-101/feed/</wfw:commentRss> <slash:comments>0</slash:comments> </item> <item><title>Shaft Displacement Measurement Using A PROTOR System</title><link>http://blog.prosig.com/2008/06/04/shaft-displacement-measurement-using-a-protor-system/</link> <comments>http://blog.prosig.com/2008/06/04/shaft-displacement-measurement-using-a-protor-system/#comments</comments> <pubDate>Wed, 04 Jun 2008 10:49:36 +0000</pubDate> <dc:creator>Don Davies</dc:creator> <category><![CDATA[applications]]></category> <category><![CDATA[signal processing]]></category> <category><![CDATA[condition monitoring]]></category> <category><![CDATA[displacement probe]]></category> <category><![CDATA[eddy probe]]></category> <category><![CDATA[oil whirl]]></category> <category><![CDATA[orbit plot]]></category> <category><![CDATA[PROTOR]]></category> <category><![CDATA[rotating machinery]]></category> <category><![CDATA[runout]]></category> <category><![CDATA[shaft]]></category> <category><![CDATA[turbine]]></category> <category><![CDATA[vibration monitoring]]></category><guid
isPermaLink="false">http://blog.prosig.com/?p=65</guid> <description><![CDATA[Shaft displacement is an important vibration measurement for rotating machines. Shaft displacement is usually monitored by non-contact shaft displacement probes such as eddy-current probes. These probes produce a voltage proportional...]]></description> <wfw:commentRss>http://blog.prosig.com/2008/06/04/shaft-displacement-measurement-using-a-protor-system/feed/</wfw:commentRss> <slash:comments>5</slash:comments> </item> <item><title>Analyzing Shaft Twist And Repairing Damaged Tachos</title><link>http://blog.prosig.com/2005/10/19/analyzing-shaft-twist-and-repairing-damaged-tachos/</link> <comments>http://blog.prosig.com/2005/10/19/analyzing-shaft-twist-and-repairing-damaged-tachos/#comments</comments> <pubDate>Wed, 19 Oct 2005 09:22:40 +0000</pubDate> <dc:creator>Dr Colin Mercer</dc:creator> <category><![CDATA[applications]]></category> <category><![CDATA[signal processing]]></category> <category><![CDATA[Butterworth]]></category> <category><![CDATA[orders]]></category> <category><![CDATA[phaseless]]></category> <category><![CDATA[rotating machinery]]></category> <category><![CDATA[runup]]></category> <category><![CDATA[shaft]]></category> <category><![CDATA[shaft encoder]]></category> <category><![CDATA[tachometer]]></category> <category><![CDATA[torsional vibration]]></category> <category><![CDATA[vibration]]></category><guid
isPermaLink="false">http://blog.prosig.com/2005/10/19/analyzing-shaft-twist-and-repairing-damaged-tachos/</guid> <description><![CDATA[A shaft has been instrumented with two shaft encoders, one at each end. Each shaft encoder gives out a once/rev pulse and a 720 pulses/rev signal. Each signal was digitised...]]></description> <wfw:commentRss>http://blog.prosig.com/2005/10/19/analyzing-shaft-twist-and-repairing-damaged-tachos/feed/</wfw:commentRss> <slash:comments>1</slash:comments> </item> <item><title>Measuring Torsional Twist &amp; Vibration Along a Shaft or Through a Geartrain</title><link>http://blog.prosig.com/2002/05/15/torsional-vibration-example/</link> <comments>http://blog.prosig.com/2002/05/15/torsional-vibration-example/#comments</comments> <pubDate>Wed, 15 May 2002 10:10:09 +0000</pubDate> <dc:creator>Dr Colin Mercer</dc:creator> <category><![CDATA[applications]]></category> <category><![CDATA[signal processing]]></category> <category><![CDATA[engine]]></category> <category><![CDATA[gear]]></category> <category><![CDATA[nvh]]></category> <category><![CDATA[orders]]></category> <category><![CDATA[rotating machinery]]></category> <category><![CDATA[shaft]]></category> <category><![CDATA[shaft encoder]]></category> <category><![CDATA[tachometer]]></category> <category><![CDATA[torsional vibration]]></category> <category><![CDATA[twist]]></category> <category><![CDATA[vibration]]></category><guid
isPermaLink="false">http://blog.prosig.com/2002/05/15/torsional-vibration-example/</guid> <description><![CDATA[The measurement of the twist angle between two points along a shaft or through a gear train may be derived from a pair of tacho signals, one at each end...]]></description> <wfw:commentRss>http://blog.prosig.com/2002/05/15/torsional-vibration-example/feed/</wfw:commentRss> <slash:comments>3</slash:comments> </item> </channel> </rss>
<!-- Served from: blog.prosig.com @ 2012-02-04 19:30:30 by W3 Total Cache -->
