Use the following sequence to get the Articulation Index (AI) vs rotational speed:
- Perform waterfall analysis on your noise signal (+ tacho). This gives you a standard waterfall display
- On the waterfall result perform the analysis
Analysis->Noise, Vibration and Harshness->Spectrum Input->Sound Quality Auto Extract
Number of Cylinders = x (set to appropriate value)
Write metrics to Input dataset = True
Set required metric to True
In this case select either $AI_ANSI or $AI_VEH.
These are different calculations with
AI_ANSI is calculated in the range 0 to 1
AI_VEH is calculated as percentage in range 0 to 100
The following two tabs change content below.
Dr Mike Donegan
Senior Software Engineer at Prosig
Mike graduated from the University of Southampton in 1979 and then went on to complete a PhD in Seismic Refraction Studies in 1982. Mike joined Prosig as a special applications engineer. He now researches & develops new algorithms for Prosig's DATS software and assists customers with data analysis issues.